Solenoid valve (Type 150)

• Direct-acting thermoplastic valve
• Fast change
• Core tube sealed by PTFE bellows
• Independent of compressed air supply
• Wide area of application
• Pilot operation.
• Diameters from DN10 to DN20
• Adjustment range: 0.0 -2.0 bar
Function
• Closed de-energised (NC)
• Pilot operation
Function of the valve
• In the resting position, the fluid pressure is formed through a servodrive in the upper part of the membrane (2), the valve is closed.
• During the connection, the pilot valve is first opened, that is, the magnet frame and the attached pilot membrane (5) goes up and releases a discharge hole at the valve outlet. This produces a depressurization above the membrane (2) and the valve opens due to the pressure of the fluid.
• In the pilot valve a liquid filling (standard: silicone oil) supports the closing effect of the spring (11). The pilot membrane (5) reliably separates the fluid from the magneto frame (10) or from the atmosphere. To clean the servo drills, the pilot valve can be easily removed after loosening the union nut (8) -with the system without pressure-. The magnet is fixed with a blind nut (15). It can rotate
freely in front of the valve body through 360°.
• La electroválvula del tipo 160 se caracteriza por una construcción de plástico maciza robusta especialmente en lo que respecta a las influencias mecánicas exteriores.
Type of construction
• Poppet valve with diaphragm seal
• Blocked conduit location
Fluids
• Liquid or gaseous neutral or aggressive liquids, technically pure, if the components of the valves that contact the fluids are resistant to the service temperature according to the Divatec resistance list!
More Specifications
Temperature of the medium
• máx. +50°C
Operating pressure
– 0.3 to max. 6 bar (see table)
Constructive size
– DN 15 – DN 50
Viscosity
– Up to approx. 38 mm² /s (cSt)
Body
• PVC-U
• PP
• PTFE
O-rings
• FPM
• EPDM
Ambient temperature
• máx. +50°C
Connection
– PVC-U: Glue sleeve
– PP: welding socket
– PTFE: threaded sleeve
Equipment socket
– Conforms to DIN 43650
Voltage
– 24V DC
– 230 V 50 Hz
Voltage tolerance
– +/-10% according to VDE 0580
Coil power
– 230V 50Hz: 6.5VA
– 24V DC: 5 watts
Connection duration (%)
– 100
Actuation time
– Opening: 30 ms to 150 ms
– Closing: 50 ms to 1 sec.
Protection
– IP 65 with socket connector for mounted equipment
– EEXM II T4 version on request.
Mounting position
– Magnet preferably at the top
– Please note the marking ‘UP’!
Option
– NO (open without power)
– Manual override
Indication
– A differential pressure of at least 0.3 bar is required for proper operation.
Follow Us!